Traditional water trucks require operators to manually open and close valves from outside the vehicle,a cumbersome process that suffers from slow response times. Furthermore, this method poses significant safety risks when working in heavy traffic, on muddy construction sites, or across rugged, off-road terrain. It also makes real-time adjustments and precise control of water flow difficult to achieve. The introduction of a cab-mounted, electronically controlled pneumatic valve system was developed specifically to address these pain points.
Leveraging the onboard air supply of the HOWO chassis, the driver can independently control the opening and closing of multiple water circuits directly from the cab. Functions such as front-mounted high-pressure flushing, rear spraying, side spraying, and high-mounted water cannons can be switched with ease. If pedestrians or obstacles are encountered, the system allows for rapid shut-off, ensuring operational safety, precise water application, and high efficiency. By redefining how water trucks are operated, this simple yet reliable electronically controlled pneumatic solution upgrades operational capabilities—serving as an essential enhancement for specialized sanitation and construction water trucks to improve their overall utility.

✅ Electrical and hydraulic systems are isolated; the electrical control box is protected from water exposure, and the design is both waterproof and shock-resistant.
✅ Independent multi-channel control allows for separate operation of front-mounted sprayers, rear-mounted sprinklers, and water cannons.
✅ The system utilizes the truck’s existing onboard air brake reservoir, ensuring a simple installation process and high reliability even when operating on rough, uneven terrain in the field.

Operating Principle:
Electrical signals control the pneumatic circuit, while compressed air drives a ball valve in the water line, enabling remote operation of the water-spraying system from the cab. The ball valve functions solely as an on/off switch, with water pressure regulated by adjusting the speed of the water pump. The system consists of four main units: an air supply unit, an electrical control panel located in the cab, a solenoid valve assembly, and a pneumatic ball valve (equipped with a pneumatic actuator).

♦ System Components:
1. Cab Control Panel: A button panel where each button corresponds to a specific water-spraying channel, outputting electrical switching signals.
2. Solenoid Valve Bank: Electropneumatic conversion components; these switch state when energized (DC 24V) to control the flow of compressed air to the pneumatic actuators.
3. Air Supply Treatment Unit: Filters, regulates pressure, and removes moisture to protect the solenoid valves and pneumatic actuators.
4. Stainless Steel Pneumatic Water Valves: Actuating components; these use air pressure to move the valve core, thereby opening or closing the water flow.
5. Air Hoses: Wiring Harnesses, and Quick-Connect Fittings: Used for the transmission of pneumatic and electrical signals.

|
Item |
Parameters |
Remark |
|
Nominal Diameter |
DN50 |
Internal threaded connection |
|
Valve Material |
304 Stainless Steel |
Resistant to silt and erosion from clear water |
|
Seat Material |
PTFE |
Wear-resistant, aging-resistant |
|
Sealing Material |
Fluororubber (FKM) |
Wear-resistant, aging-resistant |
|
Drive Gas Source |
Onboard compressed air |
0.6–0.8 MPa (6–8 bar),minimum starting air pressure ≥ 0.5 MPa |
|
Control Voltage |
DC24V |
Standard voltage for HOWO water truck |
|
Control Fuild |
Air |
The air supply is drawn from the vehicle's air reservoir |
|
Actuator Fuild |
4-8 bar |
The key to controlling the switch |
|
Nominal Pressure |
1.6MPa |
Standard operating pressure for water sprinkler pumps |
|
Mode of Action |
Normally closed |
Safety-focused,automatically shuts off water supply during a power outage |
|
Opening and closing response time |
≤1.5s |
One touch start/stop in the cab |
|
Installation Method |
Direct threaded mounting, with the actuator facing upward |
The valve body is marked with a flow direction indicator (inlet → outlet) |
|
Operating Temperature |
-20℃~+60℃ |
In low-temperature environments, take precautions against freezing and ensure systems are drained. |
♦ Operating Principle:
1. Pressing a button on the cab control panel energizes the solenoid valve coil, causing the valve spool to shift. Compressed air then enters the actuator’s drive chamber, pushing the piston and lifting the valve spool; this opens the valve, allowing water to flow through the system for spraying.
2. Releasing the button de-energizes the solenoid valve, causing it to reset. The compressed air within the actuator chamber is rapidly exhausted, and the valve spool,driven by spring force returns to its position, pressing against the valve seat to close the valve and stop the water flow.
3. The system features multiple independent circuits. These do not interfere with one another and can be operated individually or in combination.


Installation Standards:
Beyond functional advantages, a high-quality water truck relies on overall system integration. Superior functionality requires a high-standard installation process. The following outlines the standard procedure used by the CS Truck Factory for integrating an electronically controlled sprinkler system into a HOWO water truck:

1. Piping Connections: Connect the sprinkler piping according to the flow direction arrows (In ← Out) marked on the valve bodies. Use PTFE (Teflon) tape on threads to ensure a seal; do not overtighten, as this may crack the valve body. Ideally, install actuators in an upright (vertical) position to facilitate drainage and minimize sediment accumulation.
2. Air Supply Connection: Source the air supply from the vehicle’s air reservoir. Install an air service unit (filter-regulator-lubricator assembly) upstream to remove moisture and impurities, and regulate the pressure to 0.6–0.7 MPa. Use aging-resistant PU tubing (Φ6/Φ8) and ensure all quick-connect fittings are fully seated.
3. Electrical Wiring: Connect the DC24V solenoid valve—the positive terminal to the cab-mounted switch and the negative terminal to the chassis ground. Install an appropriately rated fuse in the circuit. The electronic control box must be mounted in a dry location within the cab, protected from any water exposure.
4. Wiring and Tubing Protection: Encase chassis wiring harnesses and air lines in corrugated protective conduit. Route them away from exhaust pipes and sharp metal edges to prevent abrasion or heat-induced degradation.
5. Commissioning: Once installation is complete, first pressurize the system with air and check for leaks (using soapy water on all connections). Subsequently, power on the system and test each circuit individually to verify that the switch operations, water-discharge logic, and control panel labels are all correctly aligned.
Standard Operating Procedure:
1. Pre-departure Inspection: Start the vehicle and wait for the air pressure in the reservoir to reach 0.6–0.8 MPa; check the pressure gauge. Drain any accumulated water from the air reservoir and the filter unit (air service unit).
2. Activating Sprinkling: Ensure the water pump power take-off (PTO) is functioning correctly. Press the corresponding function switch in the cab; this will trigger the solenoid valve and open the pneumatic valve, allowing water to flow from the designated nozzles. Multiple nozzle circuits can be activated simultaneously.
3. Switching Modes During Operation: Sprinkling modes can be changed at any time while the vehicle is in motion. If pedestrians or obstacles are encountered, simply release the switch; the valves will close rapidly, stopping the water flow.
4. Completion of Operations: Turn off all switches on the control panel, disengage the power take-off (PTO), and stop the water pump.
5. Winter Shutdown: All water must be drained from the valve bodies, pipelines, and the water pump to prevent the valve bodies from cracking or the valve cores from freezing due to low temperatures.

Hagyj üzenetet
Szkennelés Wechat/WhatsApp felületre :